Wide stream of hot air perfectly suits for general and additional space heating of various size: projects under construction and premises in the repair process, production shops, hangars, warehouses, base areas, workshops and utility spaces, garages, halls, etc.
Item | HP-3.000 | HP-5.000 | HP-9.000 | HP-15.000 | HP-24.000 | HP-30.000 | HP-36.000 |
Power supply, V / Hz | 220/50 | 380/50 | |||||
Maximum current, A | 13,6 | 20,5 | 13,6 | 22,7 | 36,4 | 45,5 | 55 |
Mains cable in a set | + | - | - | - | - | - | - |
Power connector | + | - | - | - | - | - | - |
Required for connecting copper cable, mm | 3×1,5 | 3×2,5 | 5×2,5 | 5×4,0 | 5×6,0 | 5×6,0 | 5×10,0 |
Heating power setting, kw |
0,026*/1,5/ 3,0 |
0,032*/3,0/ 4,5 |
0,042*/6,0/ 9,0 |
0,1*/7,5/ 15,0 |
0,1*/12,0/ 24,0 |
0,12*/15,0/ 30,0 |
0,12*/15,0/ 36,0 |
Heat air output, m³/h | 300 | 400 | 820 | 1400 | 1700 | 2400 | 2400 |
Increasing temperature, ⁰С | 30 | 34 | 33 | 32 | 42 | 37 | 44 |
Adjusting the temperature controls | + | + | + | + | + | + | + |
Duration of work, h, not more than | 24 | ||||||
Pause duration, h, not less than | 2 | ||||||
Protection class | IP20 | ||||||
Electrical safety class | I класс | ||||||
Overheating protection | + | + | + | + | + | + | + |
Forced air cooling | - | - | + | + | + | + | + |
Device dimensions (W×H×D), mm |
220×283 ×380 |
285×350 ×476 |
436×411 ×557 |
449×411 ×557 |
|||
Box dimensions (W×H×D), mm |
240×300 ×400 |
310×365 ×490 |
480×425 ×570 |
||||
Net weight, kg | 3,9 | 5,0 | 7,1 | 14,5 | 18,7 | 19,7 | 23,5 |
Gross weight, kg | 4,7 | 5,8 | 8,7 | 16,2 | 20,4 | 21,4 | 25,2 |
— High capacity (up to 36 kW) in a compact housing;
— Two power levels and ventilation mode without heating;
— High-precision temperature controller 0 ... 40 ° C;
— Automatic airflow of heating element to safe temperature at the improper shutting-off (in models of 9 kW);
— Inbuilt thermostat to prevent overheating;
— Possibility of long-term continuous use in offline mode;
— All fan heaters series are performed in a single concept with three different housing sizes.
Item | HP-2.001 | HP-3.001 | HP-5.001 |
Power supply, V / Hz | 220/50 | ||
Maximum current, A | 13,6 | 20,5 | |
Mains cable in a set | + | + | - |
Power connector | + | + | - |
Required for connecting copper cable, mm | 3×1,5 | 3×1,5 | 3×2,5 |
Heating power setting, kw | 0,026*/1,0/2,0 | 0,026*/1,5/3,0 | 0,032*/3,0/4,5 |
Heat air output, m3/h | 300 | 400 | |
Increasing temperature, ⁰С | 30 | 34 | |
Adjusting the temperature controls | + | + | + |
Duration of work, h, not more than | 24 | ||
Pause duration, h, not less than | 2 | ||
Protection class | IP20 | ||
Electrical safety class | I класс | ||
Overheating protection | + | + | + |
Forced air cooling | - | - | - |
Device dimensions (W×H×D), mm | |||
Box dimensions (W×H×D), mm | |||
Net weight, kg | |||
Gross weight, kg |
- Light and compact body;
- High temperature difference of the air flow up to 50°С;
- Two power levels and ventilation mode without heating;
- High-precision temperature controller 0 ... 40 ° C;
- Inbuilt thermostat to prevent overheating;
- Low noise level.