+7(3412) 905-410 завод в Ижевске
+7(49237) 6-05-44 завод в Киржаче
These are powerful air curtains with the installation heights up to 4.5m.
There is universal installation - horizontal and vertical.
They are used for protection of any doors of sales, office and public spaces, and for protection of large openings - shops, hangars, garages, warehouses, logistics centers and exhibition halls.
Powerful air flow from the air curtain can significantly reduce heat losses and increase comfort level near the entrance.
Item | НС-3.000TR | HC-6.000TR | HC-9.001TR | HC-12.000TR | HC-18.000TR | HC-24.000TR |
Power supply, V / Hz | 220/50 | 380/50 | 380/50 | 380/50 | 380/50 | 380/50 |
Maximum current, A | 16 | 12 | 16 | 22 | 31 | 39 |
Mains cable in a set | + | - | - | - | - | - |
Required for connecting copper cable, mm | 3×1,5 | 5×1,5 | 5×2,5 | 5×2,5 | 5×4,0 | 5×6,0 |
Method of control | Rotary switch at the case | Remote control | ||||
Heating power setting, kw |
0,08*/1,5/ 3,0 |
0,15*/4,0/ 6,0 |
0,16*/6,0/ 9,0 |
0,17*/8,0/ 12,0 |
0,17*/9,0/ 18,0 |
0,17*/12,0/ 24,0 |
Heat air output, m3/h | 600 | 1500 | 2300 | 3200 | 3200 | 3200 |
Increasing temperature, ⁰С | 15 | 12 | 12 | 12 | 17 | 23 |
Noise level at a distance of 5 m, dB (A) | 54 | 57 | 57 | 57 | 57 | 57 |
Maximum installation height, m | 2 | 3,5 | 3,5 | 3,5 | 3,5 | 3,5 |
Protection class | IP10 | IP10 | IP10 | IP10 | IP10 | IP10 |
Electrical safety class | I class | I class | I class | I class | I class | I class |
Overheating protection | + | + | + | + | + | + |
Forced air cooling | - | + | + | + | + | + |
Device dimensions (W×H×D), mm |
815×185 ×140 |
1050×240 ×220 |
1500×240 ×220 |
1950×240 ×220 |
1950×240 ×220 |
1950×240 ×220 |
Box dimensions (W×H×D), mm |
860×225 ×145 |
1060×300 ×240 |
1525×300 ×240 |
1975×300 ×240 |
1975×300 ×240 |
1975×300 ×240 |
Net weight, kg | 8,6 | 16 | 31 | 44,5 | 45 | 45 |
Gross weight, kg | 9,3 | 16,9 | 33 | 46,2 | 47 | 47 |
— Tubular heating element (TAN) with spiral corrugated ribbing increases heat transfer twice;
— Protective capillary thermostat, with fixation in the off position, provides a high safety degree during the curtains work;
— Unique electric network provides additional airflow of TAN at not properly (emergency) turn-off;
— Two stages of heating power and a wired remote control with temperature controller allow saving electric energy and easy maintaining a comfortable temperature in the room;
— In hot areas wiring is made of high-temperature wire with special silicon insulation.
Item | HC-12.500TR | HC-18.500TR | HC-24.500TR | HC-36.500TR |
Power supply, W/Hz | 380/50 | 380/50 | 380/50 | 380/50 |
Maximum current, A | 21 | 30 | 40 | 59 |
Mains cable in a set | - | - | - | - |
Required for connecting copper cable, mm | 5х2,5 | 5х4,0 | 5х6,0 | 5х10,0 |
Method of control | Remote control | |||
Heating power setting, kw | 0,17*/6,0/12,0 | 0,23*/9,0/18,0 | 0,42*/12,0/24,0 | 0,42*/18,0/36,0 |
Heat air output, m3/h | 1800/2500 | 2700/3800 | 3500/5000 | 3500/5000 |
Increasing temperature, ⁰С | 14,5 | 14,5 | 14,5 | 22 |
Noise level at a distance of 5 m, dB (A) | 63 | 63 | 63 | 63 |
Maximum installation height, m | 4,5 | 4,5 | 4,5 | 4,5 |
Protection class | IP10 | IP10 | IP10 | IP10 |
Electrical safety class | I класс | I класс | I класс | I класс |
Overheating protection | + | + | + | + |
Forced air cooling | + | + | + | + |
Device dimensions (WxHxD), mm | 1105х280х290 | 1510х280х290 | 2020х280х290 | 2020х280х290 |
Box dimensions (WxHxD), mm | 1140х325х385 | 1540х325х385 | 2060х325х385 | 2060х325х385 |
Net weight, kg | 25,5 | 33 | 47 | 50 |
Gross weight, kg | 28 | 36 | 51 | 54 |
— These are powerful industrial curtains with the installation heights up to 4.5m;
— 2 modes of air handling capacity;
— Tubular heating element (TAN) with spiral corrugated ribbing increases heat transfer twice;
— High-performance aluminium impellers of Punker (Germany) production;
— Two stages of heating power and a wired remote control with temperature controller allow saving electric energy and easy maintaining a comfortable temperature in the room;
— Protective capillary thermostat, with fixation in the off position, provides a high safety degree during the curtains work.